Explosion Proof Ducted Air Conditioner

Ambient temperature:-7℃ - 43℃, -7℃ - 52℃,-7℃ - 60℃
It can use environment refrigerant R407C,R410A,R134A besides R22 refrigerant.
Power voltage:220V/50Hz、110V/60Hz、220V/60Hz, 380/440/480V/60HZ
Cooling Capacity:2.6 -65kW/12000-220000BTU/H
EX Mark:Exd mb ib IIBT4, Exd mb ibⅡCT4
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

  • The explosion proof split ducted air conditioner is with Full range models with cooling capacity from 2.6kW to 17.5kW, from 16kW to 65kW, available in R410A, R407C, and R22; two power suppliers 230V 50Hz 1-phase and 380/400V 50Hz 3-phase.

  • The explosion proof duct Air Conditioning system provides air conditioned comfort to new and existing homes. This means you can enjoy climate controlled comfort all year round, all round the house.

Ducting reverse cycle air conditioning is designed to air condition every room of a house or office. The fan coil is installed in the ceiling space and connected via small pipes to the outdoor unit. The fan coil pumps the conditioned, dehumidified air through flexible ducting to ceiling diffuse located in each room. Available in a range of capacities with three speed fans to deliver the required volume of air.

  • The ducting heating and cooling systems are zoned to enable you to select the area of the home or office that is to be air conditioned.

        A typical layout may be: Zone 1: Bedrooms; Zone 2: Kitchen and Family Room; Zone 3: Dining and Living Room

        Features: Concealed Installation;Perfect comfort throughout every room;Reverse cycle heating & cooling;A selection           of  outlets to choose from;Wall Controller

  • This type of explosion proof duct air conditioner is up to the standards of the products quality surveillance of national explosion-proof electrification, and has obtained the explosion proof certificate . Such explosion proof split wall mount air conditioners can be used in Used in the hazard area:

       Zone 1,Zone 2 ,Groups IIA,IIB,IIC (IEC hazard area classification),

Suitable used in the temperature range:T1,T2,T3,T4

Explosion-proof mark : Exdmbib Ⅱ BT4, Exdmbib Ⅱ CT4  .Explosion proof protection can be designed according to the ambient environment.


Standards

This explosion proof split duct air conditioner  are produced based on the explosion proof equipment standards as below:

  • GB3836.1-2010《Electrical apparatus for explosive gas atmospheres Part one: General requirements and test methods》, which is equivalent to IEC60079-0:2007

  • GB3836.2-2010《Electrical apparatus for explosive gas atmospheres Part two: Flameproof enclosure “d”》,which is equivalent to IEC 60079-1:2007

  • GB3836.4-2010《Electrical apparatus for explosive gas atmospheres Part four: Intrinsic safety “i”》,which is equivalent to IEC 60079-11:2006)

  • GB3836.9-2010 《Electrical apparatus for explosive gas atmospheres Part nine: Encapsulation “m”》,which is equivalent to IEC 60079-18:2004 .

Previous: 
Next: 

Product Category

Product Inquiry
Related Information​​​​​​​
24. November 2022
Maintenance for electrical plants in hazardous areas

Explosion proof electrical equipment designed and manufactured for installation in hazardous areas with potentially explosive atmosphere are usually very safe. The new standards and directives force manufacturers to put on the market only reliable and safe products, which are realised through consta

READ MORE
no photo
24. November 2022
Importance of Temperature Class on Explosion proof Equipment

Maximum surface temperature of explosion-proof (Ex) equipment can be one of the sufficient causes of explosion if surface temperature is more than the ignition temperature of surrounding explosive atmosphere where Ex equipment installed. Temperature class is given for any Ex equipment/ system on the

READ MORE
no photo
24. November 2022
Explosion-proof equipment used on offshore platforms and ships in europe and china

On and offshore drilling of gas or oil is a high risk sector with respect to fire and explosion hazards. Therefore, the European Union has implemented Directive 92/91/EEC to protect workers on oil platforms. Additionally, to ensure the safety of operations in these potentially explosive atmospheres,

READ MORE
no photo
Form Name

We has a powerful technical team, consisting technical personals specializing on explosion protection, electronic and mechanical area...

PRODUCT LIST

CONTACT US
  Telephone: +971 52 7798611
  WhatsApp: 00971527798611
  E-mail:        sales@exproof.ae
                            explosionproof@hotmail.com
  Website:    www.exproof.com
   Address:      PO BOX 86427,DUBAI,UAE
 
Copyright © QAMAR AL SAHEL ELECTRONICS TRADING LLC All Rights Reserved     Technical Support :coverweb